HOW TO USE YOUR PARTS CATALOGUE
1- Machine type
2- Page number
Gives section number and page number within section.
3- Illustration description
4- Machine type and serial number
-CGG012300 …………………………………………: All machines up to and including indicated number.
CGG012301-CGG012345 ……………………….: All machines between and including indicated numbers.
CGG012346- …………………………………………: Machine number indicated and after.
5- Reference number
Hydraulic connections and plugs are sold equipped with gaskets. The gasket part number, with no reference number,
follows the connection or plug part number.
6- Part number
REF ……………………………………………………..: The part designated is identified on another page.
NSS ……………………………………………………..: The part is not sold separately, order the assembly or sub-assembly.
7- Description
Nouns in various languages.
8- Dimension
Indicates size of part or other qualifying information. See page entitled “Explanation of Dimension Abbreviations”.
9- Quantity
Indicates number of parts per individual part, assembly, or sub-assembly.
NOTE : “X” in quantity column indicates “use as required”.
10- CARES code
CARES code corresponding to the part reference number.
***** ………………………………………………………: Use the CARES code for the function concerned.
11- Assembly or sub-assembly
Shown with brackets or a dotted box.
Within brackets ………………………………………: The sign ò indicates from reference number 2 up to reference
number 9.
12- Dot
Part not serviced separately.
13- Additional information
See page 7-3 …………………………………………: The part illustrated is identified on another page.
See N.I.T. 3066 ………………………………………: Consult Technical Information Note number 3066.
Replaces K2242371 ………………………………: The part number was previously K2242371.
Order K2242371 ……………………………………: The part number has been replaced. Order K2242371.
Order length 1250 mm …………………………..: Part sold by the metre, order quantity 1.25.
Left, Right, Front and Rear ……………………: “Right”, everything to the right of the operator when the seat is in
backhoe attachment or loader attachment position.
Kit containing X ……………………………………: Kit containing X identical parts.
Version XXXXX………………………………………: Special version or specific supplier.
Consists of ref. numbers 1-5, 9, 13 ………..: The assembly consists of parts reference numbers 1 to 5, 9 and 13.
Consists of pages 2-3, 2-7 – 2-11 ……………: The assembly consists of parts pages 2-3 and 2-7 to 2-11.
14- Catalogue reference number
15- Date of issue
16- Illustration reference
17- Replaced by
The arrow indicates the new part(s).
The new part(s) is (are) fully interchangeable with the old part(s).
18- Interchangeable
The parts or parts assemblies are fully interchangeable.
TABLE OF CONTENTS:
Case Excavators 1288 Demolition Attachment Parts Catalog Manual_EN_FR_DE(7-3621) – PDF DOWNLOAD
Attachment – Control Block . . . . . . . . . . . . . . . . . . . . 2-173
B
Boom (6.50 m – 256 in) – Clamshell Swing Feed . . . . 2-47
Boom (6.50 m – 256 in) – Dipper Cylinder Circuit . . . . 2-51
Boom (870 m – 342-5/8 in) – Hydraulic Circuit . . . . . . 2-65
Boom (8.70 m – 342-5/8 in) . . . . . . . . . . . . . . . . 2-61 2-63
Boom (8.70 m – 342-5/8 in) – Clamshell Swing Feed . 2-69
Boom (8.70 m – 342-5/8 in) – Lubrication Circuit . . . . . 2-73
Boom (8.70 m – 342-5/8 in) – Pick Hammer Circuit . . . 2-71
Boom – Extension (4.20 m – 165-3/8 in) . . . . . . . . . . 2-117
Boom – Extension (4.60 m – 181-1/8 in) . . . . . . . . . . 2-127
Boom – Safety Valve . . . . . . . . . . . . . . . . . . . . . 2-57 2-59
Boom Cylinder . . . . . . . . . . . . . . . . . . . . . . . . 2-83 2-103
Boom Cylinder Circuit . . . . . . . . . . . . . . . . . . . . . . . . . 2-77
Boom Cylinder Circuit – Safety Device
. . . . . . . . . . . . . . . . . . . . . . . . . 2-79 2-81 2-99 2-101
Boom Hydraulic Circuit – Extension (3.20 m – 126 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-119 – 2-123
Boom Hydraulic Circuit – Extension (4.60 m – 181-1/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-129 – 2-133
Bucket Control – Dipper (5.50 m – 216-5/8 in) . . . . . . 2-167
Bucket Control Feed – Dipper (4.50 m – 177-1/4 in) . . 2-91
Bucket Cylinder – Dipper (5.50 m – 216-5/8 in) . . . . . 2-171
Bucket Cylinder Circuit – Dipper (5.50 m – 216-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Bucket Cylinder Protection – Dipper (5.50 m – 216-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
C
Cab Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-185
Clamshell Feed – Fast Coupler . . . . . . . . . . . . . . . . . 2-179
Clamshell Swing Feed – Boom (6.50 m – 256 in) . . . . 2-47
Clamshell Swing Feed – Boom (8.70 m – 342-5/8 in) . 2-69
Clamshell Swing Feed – Dipper (4.50 m – 177-1/4 in) . 2-95
Control Block – Attachment . . . . . . . . . . . . . . . . . . . . 2-173
Control Valve – High Flow . . . . . . . . . . . . . . . . . . . . . . 2-23
Control Valve – Option Section (30L/mn) . . . . . . . . . . 2-35
Control Valve – Option Section (60L/mn) . . . . . . . . . . 2-33
Control Valve – Optional . . . . . . . . . . . . . . . . . . . . . . . 2-31
Control Valve Attachment – Pilot Circuit . . . . . . . . . . . 2-37
Cooler Grating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-187
Counterweight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
D
Decals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-181
Decals (8.70 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . 2-75
Demolition – Hydraulic Circuit . . . . . 2-17 2-25 2-27 2-39
Dipper (4.50 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . 2-89
Dipper (4.50 m – 177-1/4 in) – Bucket Control Feed . . 2-91
Dipper (4.50 m – 177-1/4 in) – Clamshell Swing Feed . 2-95
Dipper (4.50 m – 177-1/4 in) – Lubrication Circuit . . . . 2-97
Dipper (4.50 m – 177-1/4 in) – Pick Hammer Circuit . . 2-93
D
Dipper (5.50 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . 2-143
Dipper (5.50 m – 216-5/8 in) – Bucket Control . . . . . . 2-167
Dipper (5.50 m – 216-5/8 in) – Bucket Cylinder . . . . . 2-171
Dipper (5.50 m – 216-5/8 in) – Bucket Cylinder Circuit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Dipper (5.50 m – 216-5/8 in) – Bucket Cylinder Protection
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
Dipper (5.50 m – 216-5/8 in) – Hydraulic Circuit . . . . . 2-145
Dipper – Safety Valve . . . . . . . . . . . . . . . . . . 2-157 – 2-163
Dipper Cylinder . . . . . . . . . . . . . . . . . . . . . . . . 2-53 2-155
Dipper Cylinder (4.50 m – 177-1/4 in) – Hydraulic Circuit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Dipper Cylinder Circuit . . . . . . . . . . . . . . . . . 2-151 2-153
Dipper Cylinder Circuit (8.70 m – 342-5/8 in) . . . . . . . . 2-67
Dipper Cylinder Circuit – Boom (6.50 m – 256 in) . . . . 2-51
E
Electric Circuit Attachment . . . . . . . . . . . . . . . . . . . . 2-147
F
Fast Coupler – Clamshell Feed . . . . . . . . . . . . . . . . . 2-179
H
Handling Boom (6.50 m – 256 in) . . . . . . . . . . . . . . . . 2-41
Handling Boom (6.50 m – 256 in) – Hydraulic Circuit . . 2-43
Handling Boom (6.50 m – 256 in) – Lubrication Circuit 2-45
Handling Boom (6.50 m – 256 in) – Pick Hammer Circuit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
High Flow – Control Valve . . . . . . . . . . . . . . . . . . . . . . 2-23
Hydraulic Circuit – Boom (870 m – 342-5/8 in) . . . . . . 2-65
Hydraulic Circuit – Demolition . . . . . 2-17 2-25 2-27 2-39
Hydraulic Circuit – Dipper (5.50 m – 216-5/8 in) . . . . . 2-145
Hydraulic Circuit – Dipper Cylinder (4.50 m – 177-1/4 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Hydraulic Circuit – Handling Boom (6.50 m – 256 in) . . 2-43
Hydraulic Circuit – Intermediate Dipper (2.40 m – 94-1/2 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Hydraulic Circuit – Operators Compartment . . . 2-15 2-29
Hydraulic Circuit – Pre-Boom (3.20 m – 126 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Hydraulic Circuit – Upperstructure Chassis . . . . 2-9 – 2-13
Hydraulic Circuit High Flow – Upperstructure Chassis
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
I
Intermediate Dipper (2.40 m – 94-1/2 in) . . . . . . . . . . 2-137
Intermediate Dipper (2.40 m – 94-1/2 in) – Hydraulic Circuit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Intermediate Dipper (2.40 m – 94-1/2 in) – Lubrication Circuit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Intermediate Dipper Cylinder . . . . . . . . . . . . . . . . . . 2-165
Intermediate Dipper Cylinder Circuit . . . . . . . . . . . . . 2-149
Lubrication Circuit – Boom (8.70 m – 342-5/8 in) . . . . 2-73
Lubrication Circuit – Dipper (4.50 m – 177-1/4 in) . . . . 2-97
Lubrication Circuit – Handling Boom (6.50 m – 256 in) 2-45
Lubrication Circuit – Intermediate Dipper (2.40 m – 94-1/2 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Lubrication Circuit – Pre-Boom (3.20 m – 126 in) . . . 2-115
Lubrication Circuit Boom – Extension (3.20 m – 126 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-125
Lubrication Circuit Boom – Extension (4.60 m – 181-1/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-135
O
Operators Compartment – Hydraulic Circuit . . . 2-15 2-29
Option Section (30L/mn) – Control Valve . . . . . . . . . . 2-35
Option Section (60L/mn) – Control Valve . . . . . . . . . . 2-33
Overload Indicator – Safety Valve . . . . . . . . . . . 2-85 2-87
P
Pick Hammer Circuit – Boom (8.70 m – 342-5/8 in) . . 2-71
Pick Hammer Circuit – Dipper (4.50 m – 177-1/4 in) . . 2-93
Pick Hammer Circuit – Handling Boom (6.50 m – 256 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
Pilot Circuit – Control Valve Attachment . . . . . . . . . . 2-37
Pre-Boom (3.20 m – 126 in) . . . . . . . . . . . . . . . . . . . 2-105
Pre-Boom (3.20 m – 126 in) – Hydraulic Circuit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Pre-Boom (3.20 m – 126 in) – Lubrication Circuit . . . 2-115
S
Safety Device – Boom Cylinder Circuit
. . . . . . . . . . . . . . . . . . . . . . . . . . 2-79 2-81 2-99 2-101
Safety Valve – Boom . . . . . . . . . . . . . . . . . . . . . 2-57 2-59
Safety Valve – Dipper . . . . . . . . . . . . . . . . . . 2-157 – 2-163
Safety Valve – Overload Indicator . . . . . . . . . . . 2-85 2-87
Selection Shutoff . . . . . . . . . . . . . . . . . . . . . . 2-175 2-177
U
Upperstructure Chassis . . . . . . . . . . . . . . . . . . . . . 2-3 2-5
Upperstructure Chassis – Hydraulic Circuit . . . . 2-9 – 2-13
Upperstructure Chassis – Hydraulic Circuit High Flow
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Upperstructure Guard . . . . . . . . . . . . . . . . . . . . . . . 2-183
Adhesifs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-181
Adhesifs (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . 2-75
Alimentation Benne – Coupleur Rapide . . . . . . . . . . . 2-179
Alimentation Commande Godet – Balancier (450 m – 177-1/
4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-91
Alimentation Rotation Benne – Balancier (450 m – 177-1/4
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95
Alimentation Rotation Benne – Fleche (650 m – 256 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
Alimentation Rotation Benne – Fleche (870 m – 342-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
B
Balancier (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . 2-89
Balancier (450 m – 177-1/4 in) – Alimentation Commande
Godet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-91
Balancier (450 m – 177-1/4 in) – Alimentation Rotation
Benne . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95
Balancier (450 m – 177-1/4 in) – Circuit De Graissage 2-97
Balancier (450 m – 177-1/4 in) – Circuit Marteau Piqueur
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Balancier (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . 2-143
Balancier (550 m – 216-5/8 in) – Circuit Hydraulique 2-145
Balancier (550 m – 216-5/8 in) – Circuit Verin De Godet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Balancier (550 m – 216-5/8 in) – Commande Godet . 2-167
Balancier (550 m – 216-5/8 in) – Protection Verin De Godet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
Balancier (550 m – 216-5/8 in) – Verin De Godet . . . 2-171
Balancier – Valve De Securite . . . . . . . . . . . 2-157 – 2-163
Balancier Intermediaire (240 m – 94-1/2 in
HYDRAULIKKREISLAUF – PENDELARMZWISCHENSTÜCK
240 m – 94-1/2 in) – Circuit
Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Balancier Intermediaire (240 m – 94-1/2 in) . . . . . . . 2-137
Balancier Intermediaire (240 m – 94-1/2 in) – Circuit De
Graissage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Bloc De Commande – Equipement . . . . . . . . . . . . . . 2-173
C
Chassis Tourelle . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-5
Chassis Tourelle – Circuit Hydraulique . . . . . . . 2-9 – 2-13
Chassis Tourelle – Circuit Hydraulique Grand Debit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Circuit De Graissage – Balancier (450 m – 177-1/4 in) 2-97
Circuit De Graissage – Balancier Intermediaire (240 m – 94-
1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Circuit De Graissage – Fleche (870 m – 342-5/8 in) . . 2-73
Circuit De Graissage – Fleche Manutention (650 m – 256 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Circuit De Graissage – Prefleche (320 m – 126 in) . . 2-115
Circuit De Graissage Fleche – Rallonge (320 m – 126 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-125
C
Circuit De Graissage Fleche – Rallonge (460 m – 181-1/8
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-135
Circuit De Pilotage – Distributeur Equipement . . . . . . 2-37
Circuit Electrique Equipement . . . . . . . . . . . . . . . . . 2-147
Circuit Hydraulique – Balancier (550 m – 216-5/8 in) 2-145
Circuit Hydraulique – Balancier Intermediaire (240 m – 94-1/
2 in HYDRAULIKKREISLAUF – PENDELARMZWISCHENSTÜCK
240 m – 94-1/2 in) . . . . . . . . 2-139
Circuit Hydraulique – Chassis Tourelle . . . . . . . 2-9 – 2-13
Circuit Hydraulique – Demolition . . . 2-17 2-25 2-27 2-39
Circuit Hydraulique – Fleche (870 m – 342-5/8 in) . . . 2-65
Circuit Hydraulique – Fleche Manutention (650 m – 256 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Circuit Hydraulique – Poste De Conduite . . . . . . 2-15 2-29
Circuit Hydraulique – Prefleche (320 m – 126 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Circuit Hydraulique – Verin De Balancier (450 m – 177-1/4
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Circuit Hydraulique Fleche – Rallonge (320 m – 126 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-119 – 2-123
Circuit Hydraulique Fleche – Rallonge (460 m – 181-1/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-129 – 2-133
Circuit Hydraulique Grand Debit – Chassis Tourelle
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Circuit Marteau Piqueur – Balancier (450 m – 177-1/4 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Circuit Marteau Piqueur – Fleche (870 m – 342-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71
Circuit Marteau Piqueur – Fleche Manutention (650 m – 256
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
Circuit Verin De Balancier . . . . . . . . . . . . . . . 2-151 2-153
Circuit Verin De Balancier (870 m – 342-5/8 in) . . . . . 2-67
Circuit Verin De Balancier – Fleche (650 m – 256 in) . 2-51
Circuit Verin De Balancier Intermediaire . . . . . . . . . . 2-149
Circuit Verin De Fleche . . . . . . . . . . . . . . . . . . . . . . . . 2-77
Circuit Verin De Fleche – Securite . 2-79 2-81 2-99 2-101
Circuit Verin De Godet – Balancier (550 m – 216-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Commande Godet – Balancier (550 m – 216-5/8 in) . 2-167
Contrepoids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Coupleur Rapide – Alimentation Benne . . . . . . . . . . . 2-179
D
Demolition – Circuit Hydraulique . . . 2-17 2-25 2-27 2-39
Distributeur – Element Option (30L/mn) . . . . . . . . . . . 2-35
Distributeur – Element Option (60L/mn) . . . . . . . . . . . 2-33
Distributeur – Grand Debit . . . . . . . . . . . . . . . . . . . . . . 2-23
Distributeur – Option . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Distributeur Equipement – Circuit De Pilotage . . . . . . 2-37
E
Element Option (30L/mn) – Distributeur . . . . . . . . . . . 2-35
Element Option (60L/mn) – Distributeur . . . . . . . . . . . 2-33
Equipement – Bloc De Commande . . . . . . . . . . . . . 2-173
F
Fleche (650 m – 256 in) – Alimentation Rotation Benne
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
Fleche (650 m – 256 in) – Circuit Verin De Balancier 2-51
Fleche (870 m – 342-5/8 in) . . . . . . . . . . . . . . . 2-61 2-63
Fleche (870 m – 342-5/8 in) – Alimentation Rotation Benne
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
Fleche (870 m – 342-5/8 in) – Circuit De Graissage . 2-73
Fleche (870 m – 342-5/8 in) – Circuit Hydraulique . . . 2-65
Fleche (870 m – 342-5/8 in) – Circuit Marteau Piqueur
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71
Fleche – Rallonge (420 m – 165-3/8 in) . . . . . . . . . . 2-117
Fleche – Rallonge (460 m – 181-1/8 in) . . . . . . . . . . 2-127
Fleche – Valve De Securite . . . . . . . . . . . . . . . . 2-57 2-59
Fleche Manutention (650 m – 256 in) . . . . . . . . . . . . 2-41
Fleche Manutention (650 m – 256 in) – Circuit De Graissage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Fleche Manutention (650 m – 256 in) – Circuit Hydraulique
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Fleche Manutention (650 m – 256 in) – Circuit Marteau
Piqueur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
G
Grand Debit – Distributeur . . . . . . . . . . . . . . . . . . . . . 2-23
I
Indicateur De Surcharge – Valve De Securite . . 2-85 2-87
P
Poste De Conduite – Circuit Hydraulique . . . . . . 2-15 2-29
Prefleche (320 m – 126 in) . . . . . . . . . . . . . . . . . . . 2-105
Prefleche (320 m – 126 in) – Circuit De Graissage . 2-115
Prefleche (320 m – 126 in) – Circuit Hydraulique
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Protection Cabine . . . . . . . . . . . . . . . . . . . . . . . . . . 2-185
Protection Refrigerant . . . . . . . . . . . . . . . . . . . . . . . 2-187
Protection Tourelle . . . . . . . . . . . . . . . . . . . . . . . . . . 2-183
Protection Verin De Godet – Balancier (550 m – 216-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
R
Robinet De Selection . . . . . . . . . . . . . . . . . . . 2-175 2-177
S
Securite – Circuit Verin De Fleche . 2-79 2-81 2-99 2-101
V
Valve De Securite – Balancier . . . . . . . . . . . 2-157 – 2-163
Valve De Securite – Fleche . . . . . . . . . . . . . . . . 2-57 2-59
Valve De Securite – Indicateur De Surcharge . . 2-85 2-87
V
Verin De Balancier . . . . . . . . . . . . . . . . . . . . . . 2-53 2-155
Verin De Balancier (450 m – 177-1/4 in) – Circuit
Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Verin De Balancier Intermediaire . . . . . . . . . . . . . . . 2-165
Verin De Fleche . . . . . . . . . . . . . . . . . . . . . . . . 2-83 2-103
Verin De Godet – Balancier (550 m – 216-5/8 in) . . . 2-171
Abrissarbeit – Hydraulikkreislauf . . . 2-17 2-25 2-27 2-39
Aufkleber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-181
Aufkleber (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . 2-75
Ausleger (650 m – 256 in) – Eingabe Der Greiferdrehung
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
Ausleger (650 m – 256 in) – Kreislauf Pendelarmzylinder
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
Ausleger (870 m – 342-5/8 in) . . . . . . . . . . . . . 2-61 2-63
Ausleger (870 m – 342-5/8 in) – Eingabe Der
Greiferdrehung . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
Ausleger (870 m – 342-5/8 in) – Hydraulikkreislauf . . . 2-65
Ausleger (870 m – 342-5/8 in) – Kreislauf
Hammerwerkzeuge . . . . . . . . . . . . . . . . . . . . . . . . 2-71
Ausleger (870 m – 342-5/8 in) – Schmierkreis . . . . . . 2-73
Ausleger – Sicherheitsventil . . . . . . . . . . . . . . . . 2-57 2-59
Ausleger – Verlängerung (420 m – 165-3/8 in) . . . . . 2-117
Ausleger – Verlängerung (460 m – 181-1/8 in) . . . . . 2-127
Auslegerzylinder . . . . . . . . . . . . . . . . . . . . . . . 2-83 2-103
Ausrüstung – Steuerblock . . . . . . . . . . . . . . . . . . . . . 2-173
E
Eingabe Der Greiferdrehung – Ausleger (650 m – 256 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
Eingabe Der Greiferdrehung – Ausleger (870 m – 342-5/8
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
Eingabe Der Greiferdrehung – Pendelarm (450 m – 177-1/4
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95
Eingabe Der Löffelbetätigung – Pendelarm (450 m – 177-1/
4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-91
Elektrokreis Ausrüstung . . . . . . . . . . . . . . . . . . . . . . 2-147
Element Für Zusatzausstattung (30L/mn) – Steuergerät
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Element Für Zusatzausstattung (60L/mn) – Steuergerät
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
F
Fahrerstand – Hydraulikkreislauf . . . . . . . . . . . . 2-15 2-29
G
Gegengewicht . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Greifer-Versorgung – Schnellkuppler . . . . . . . . . . . . . 2-179
Grundausleger (320 m – 126 in) . . . . . . . . . . . . . . . . 2-105
Grundausleger (320 m – 126 in) – Hydraulikkreislauf
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Grundausleger (320 m – 126 in) – Schmierkreis . . . . 2-115
H
Handhabung Ausleger (650 m – 256 in) . . . . . . . . . . . 2-41
Handhabung Ausleger (650 m – 256 in) – Hydraulikkreislauf
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Handhabung Ausleger (650 m – 256 in) – Kreislauf
Hammerwerkzeuge . . . . . . . . . . . . . . . . . . . . . . . . 2-49
H
Handhabung Ausleger (650 m – 256 in) – Schmierkreis
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Hoher Durchfluss – Steuergerät . . . . . . . . . . . . . . . . . 2-23
Hydraulikkreis Für Ausleger – Verlängerung (320 m – 126
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-119 – 2-123
Hydraulikkreis Für Ausleger – Verlängerung (460 m – 181-1/
8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-129 – 2-133
Hydraulikkreislauf – Abrissarbeit . . . 2-17 2-25 2-27 2-39
Hydraulikkreislauf – Ausleger (870 m – 342-5/8 in) . . . 2-65
Hydraulikkreislauf – Fahrerstand . . . . . . . . . . . . 2-15 2-29
Hydraulikkreislauf – Grundausleger (320 m – 126 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Hydraulikkreislauf – Handhabung Ausleger (650 m – 256 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Hydraulikkreislauf – Pendelarm (550 m – 216-5/8 in) 2-145
Hydraulikkreislauf – Pendelarm-Zwischenstück . . . . . 2-139
Hydraulikkreislauf – Pendelarmzylinder (450 m – 177-1/4 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Hydraulikkreislauf – Rahmen Oberwagen . . . . . 2-9 – 2-13
Hydraulikkreislauf Hoher Durchfluss – Rahmen Oberwagen
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
K
Kabineschutzvorrichtung . . . . . . . . . . . . . . . . . . . . . . 2-185
Kreislauf Auslegerzylinder . . . . . . . . . . . . . . . . . . . . . . 2-77
Kreislauf Auslegerzylinder – Sicherheitsventil
. . . . . . . . . . . . . . . . . . . . . . . . . 2-79 2-81 2-99 2-101
Kreislauf Hammerwerkzeuge – Ausleger (870 m – 342-5/8
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71
Kreislauf Hammerwerkzeuge – Handhabung Ausleger (650
m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
Kreislauf Hammerwerkzeuge – Pendelarm (450 m – 177-1/4
in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Kreislauf Löffelzylinder – Pendelarm (550 m – 216-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Kreislauf Pendelarm-Zwischenstückzylinder . . . . . . . 2-149
Kreislauf Pendelarmzylinder . . . . . . . . . . . . . 2-151 2-153
Kreislauf Pendelarmzylinder (870 m – 342-5/8 in) . . . 2-67
Kreislauf Pendelarmzylinder – Ausleger (650 m – 256 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
Kühlergrill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-187
L
Löffelbetätigung – Pendelarm (550 m – 216-5/8 in) . 2-167
Löffelzylinder – Pendelarm (550 m – 216-5/8 in) . . . . 2-171
Löffelzylinderschutz – Pendelarm (550 m – 216-5/8 in)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
O
Oberwagenschutzvorrichtung . . . . . . . . . . . . . . . . . . 2-183
P
Pendelarm (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . 2-89
Dipper Cylinder (4.50 m – 177-1/4 in) – Hydraulic Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Dipper Cylinder Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-151 2-153
Dipper Cylinder Circuit (8.70 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67
Dipper Cylinder Circuit – Boom (6.50 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
Electric Circuit Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-147
Fast Coupler – Clamshell Feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-179
Handling Boom (6.50 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-41
Handling Boom (6.50 m – 256 in) – Hydraulic Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Handling Boom (6.50 m – 256 in) – Lubrication Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Handling Boom (6.50 m – 256 in) – Pick Hammer Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
High Flow – Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23
Hydraulic Circuit – Boom (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65
Hydraulic Circuit – Demolition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 2-25 2-27 2-39
Hydraulic Circuit – Dipper (5.50 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-145
Hydraulic Circuit – Dipper Cylinder (4.50 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Hydraulic Circuit – Handling Boom (6.50 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Hydraulic Circuit – Intermediate Dipper (2.40 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Hydraulic Circuit – Operators Compartment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15 2-29
Hydraulic Circuit – Pre-Boom (3.20 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Hydraulic Circuit – Upperstructure Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 – 2-13
Hydraulic Circuit High Flow – Upperstructure Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Intermediate Dipper (2.40 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-137
Intermediate Dipper (2.40 m – 94-1/2 in) – Hydraulic Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Intermediate Dipper (2.40 m – 94-1/2 in) – Lubrication Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Intermediate Dipper Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-165
Intermediate Dipper Cylinder Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-149
Lubrication Circuit – Boom (8.70 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73
Lubrication Circuit – Dipper (4.50 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-97
Lubrication Circuit – Handling Boom (6.50 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Lubrication Circuit – Intermediate Dipper (2.40 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Lubrication Circuit – Pre-Boom (3.20 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-115
Lubrication Circuit Boom – Extension (3.20 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-125
Lubrication Circuit Boom – Extension (4.60 m – 181-1/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-135
Operators Compartment – Hydraulic Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15 2-29
Option Section (30L/mn) – Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Option Section (60L/mn) – Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Overload Indicator – Safety Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 2-87
Pick Hammer Circuit – Boom (8.70 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71
Pick Hammer Circuit – Dipper (4.50 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Pick Hammer Circuit – Handling Boom (6.50 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
Pilot Circuit – Control Valve Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37
Pre-Boom (3.20 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-105
Pre-Boom (3.20 m – 126 in) – Hydraulic Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Pre-Boom (3.20 m – 126 in) – Lubrication Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-115
Safety Device – Boom Cylinder Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-79 2-81 2-99 2-101
Safety Valve – Boom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57 2-59
Safety Valve – Dipper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-157 – 2-163
Safety Valve – Overload Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 2-87
Selection Shutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-175 2-177
Upperstructure Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-5
Upperstructure Chassis – Hydraulic Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 – 2-13
Upperstructure Chassis – Hydraulic Circuit High Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Upperstructure Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-183
Adhesifs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-181
Adhesifs (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-75
Alimentation Benne – Coupleur Rapide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-179
Alimentation Commande Godet – Balancier (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-91
Alimentation Rotation Benne – Balancier (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95
Alimentation Rotation Benne – Fleche (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
Alimentation Rotation Benne – Fleche (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
Balancier (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-89
Balancier (450 m – 177-1/4 in) – Alimentation Commande Godet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-91
Balancier (450 m – 177-1/4 in) – Alimentation Rotation Benne . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95
Balancier (450 m – 177-1/4 in) – Circuit De Graissage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-97
Balancier (450 m – 177-1/4 in) – Circuit Marteau Piqueur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Balancier (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-143
Balancier (550 m – 216-5/8 in) – Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-145
Balancier (550 m – 216-5/8 in) – Circuit Verin De Godet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Balancier (550 m – 216-5/8 in) – Commande Godet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-167
Balancier (550 m – 216-5/8 in) – Protection Verin De Godet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
Balancier (550 m – 216-5/8 in) – Verin De Godet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-171
Balancier – Valve De Securite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-157 – 2-163
Balancier Intermediaire (240 m – 94-1/2 in HYDRAULIKKREISLAUF – PENDELARM-ZWISCHENSTÜCK 240 m – 94-1/2 in)
– Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Balancier Intermediaire (240 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-137
Balancier Intermediaire (240 m – 94-1/2 in) – Circuit De Graissage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Bloc De Commande – Equipement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-173
Chassis Tourelle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-5
Chassis Tourelle – Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 – 2-13
Chassis Tourelle – Circuit Hydraulique Grand Debit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Circuit De Graissage – Balancier (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-97
Circuit De Graissage – Balancier Intermediaire (240 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Circuit De Graissage – Fleche (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73
Circuit De Graissage – Fleche Manutention (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Circuit De Graissage – Prefleche (320 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-115
Circuit De Graissage Fleche – Rallonge (320 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-125
Circuit De Graissage Fleche – Rallonge (460 m – 181-1/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-135
Circuit De Pilotage – Distributeur Equipement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37
Circuit Electrique Equipement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-147
Circuit Hydraulique – Balancier (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-145
Circuit Hydraulique – Balancier Intermediaire (240 m – 94-1/2 in HYDRAULIKKREISLAUF – PENDELARMZWISCHENSTÜCK
240 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Circuit Hydraulique – Chassis Tourelle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 – 2-13
Circuit Hydraulique – Demolition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 2-25 2-27 2-39
Circuit Hydraulique – Fleche (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65
Circuit Hydraulique – Fleche Manutention (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Circuit Hydraulique – Poste De Conduite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15 2-29
Circuit Hydraulique – Prefleche (320 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Circuit Hydraulique – Verin De Balancier (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Circuit Hydraulique Fleche – Rallonge (320 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-119 – 2-123
Circuit Hydraulique Fleche – Rallonge (460 m – 181-1/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-129 – 2-133
Circuit Hydraulique Grand Debit – Chassis Tourelle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Circuit Marteau Piqueur – Balancier (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Circuit Marteau Piqueur – Fleche (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71
Circuit Marteau Piqueur – Fleche Manutention (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
Circuit Verin De Balancier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-151 2-153
Circuit Verin De Balancier (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67
Circuit Verin De Balancier – Fleche (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
Circuit Verin De Balancier Intermediaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-149
Circuit Verin De Fleche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-77
Circuit Verin De Fleche – Securite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-79 2-81 2-99 2-101
Circuit Verin De Godet – Balancier (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Commande Godet – Balancier (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-167
Contrepoids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Coupleur Rapide – Alimentation Benne . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-179
Demolition – Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 2-25 2-27 2-39
Distributeur – Element Option (30L/mn) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Distributeur – Element Option (60L/mn) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Distributeur – Grand Debit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23
Distributeur – Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Distributeur Equipement – Circuit De Pilotage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37
Element Option (30L/mn) – Distributeur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Element Option (60L/mn) – Distributeur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Equipement – Bloc De Commande . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-173
Fleche (650 m – 256 in) – Alimentation Rotation Benne . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
Fleche (650 m – 256 in) – Circuit Verin De Balancier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
Fleche (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61 2-63
Fleche (870 m – 342-5/8 in) – Alimentation Rotation Benne . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
Fleche (870 m – 342-5/8 in) – Circuit De Graissage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73
Fleche (870 m – 342-5/8 in) – Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65
Fleche (870 m – 342-5/8 in) – Circuit Marteau Piqueur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71
Fleche – Rallonge (420 m – 165-3/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-117
Fleche – Rallonge (460 m – 181-1/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-127
Fleche – Valve De Securite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57 2-59
Fleche Manutention (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-41
Fleche Manutention (650 m – 256 in) – Circuit De Graissage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Fleche Manutention (650 m – 256 in) – Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Fleche Manutention (650 m – 256 in) – Circuit Marteau Piqueur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
Grand Debit – Distributeur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23
Indicateur De Surcharge – Valve De Securite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 2-87
Poste De Conduite – Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15 2-29
Prefleche (320 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-105
Prefleche (320 m – 126 in) – Circuit De Graissage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-115
Prefleche (320 m – 126 in) – Circuit Hydraulique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107 – 2-113
Protection Cabine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-185
Protection Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-187
Protection Tourelle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-183
Protection Verin De Godet – Balancier (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
Robinet De Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-175 2-177
Securite – Circuit Verin De Fleche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-79 2-81 2-99 2-101
Valve De Securite – Balancier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-157 – 2-163
Valve De Securite – Fleche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57 2-59
Valve De Securite – Indicateur De Surcharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 2-87
Kreislauf Hammerwerkzeuge – Pendelarm (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Kreislauf Löffelzylinder – Pendelarm (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Kreislauf Pendelarm-Zwischenstückzylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-149
Kreislauf Pendelarmzylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-151 2-153
Kreislauf Pendelarmzylinder (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67
Kreislauf Pendelarmzylinder – Ausleger (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
Kühlergrill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-187
Löffelbetätigung – Pendelarm (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-167
Löffelzylinder – Pendelarm (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-171
Löffelzylinderschutz – Pendelarm (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
Oberwagenschutzvorrichtung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-183
Pendelarm (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-89
Pendelarm (450 m – 177-1/4 in) – Eingabe Der Greiferdrehung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95
Pendelarm (450 m – 177-1/4 in) – Eingabe Der Löffelbetätigung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-91
Pendelarm (450 m – 177-1/4 in) – Kreislauf Hammerwerkzeuge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
Pendelarm (450 m – 177-1/4 in) – Schmierkreis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-97
Pendelarm (550 m – 216-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-143
Pendelarm (550 m – 216-5/8 in) – Hydraulikkreislauf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-145
Pendelarm (550 m – 216-5/8 in) – Kreislauf Löffelzylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-169
Pendelarm (550 m – 216-5/8 in) – Löffelbetätigung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-167
Pendelarm (550 m – 216-5/8 in) – Löffelzylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-171
Pendelarm (550 m – 216-5/8 in) – Löffelzylinderschutz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
Pendelarm – Sicherheitsventil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-157 – 2-163
Pendelarm-Zwischenstück (240 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-137
Pendelarm-Zwischenstück (240 m – 94-1/2 in) – Schmierkreis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Pendelarm-Zwischenstück – Hydraulikkreislauf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
Pendelarm-Zwischenstückzylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-165
Pendelarmzylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53 2-155
Pendelarmzylinder (450 m – 177-1/4 in) – Hydraulikkreislauf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
Rahmen Oberwagen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-5
Rahmen Oberwagen – Hydraulikkreislauf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 – 2-13
Rahmen Oberwagen – Hydraulikkreislauf Hoher Durchfluss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 2-21
Schmierkreis – Ausleger (870 m – 342-5/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73
Schmierkreis – Grundausleger (320 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-115
Schmierkreis – Handhabung Ausleger (650 m – 256 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
Schmierkreis – Pendelarm (450 m – 177-1/4 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-97
Schmierkreis – Pendelarm-Zwischenstück (240 m – 94-1/2 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-141
Schmierkreislauf Ausleger – Verlängerung (320 m – 126 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-125
Schmierkreislauf Ausleger – Verlängerung (460 m – 181-1/8 in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-135
Schnellkuppler – Greifer-Versorgung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-179
Sicherheitsventil – Ausleger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57 2-59
Sicherheitsventil – Kreislauf Auslegerzylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-79 2-81 2-99 2-101
Sicherheitsventil – Pendelarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-157 – 2-163
Sicherheitsventil – Überlastanzeiger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 2-87
Steuerblock – Ausrüstung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-173
Steuergerät – Element Für Zusatzausstattung (30L/mn) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Steuergerät – Element Für Zusatzausstattung (60L/mn) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Steuergerät – Hoher Durchfluss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23
Steuergerät – Zusatzausführung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Steuergerät Zubehör – Steuerkreis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37
IMAGES PREVIEW OF THE MANUAL:
PLEASE NOTE:
- This is the SAME MANUAL used by dealerships to diagnose your vehicle
- No waiting for couriers/posts as this is a PDF manual and you can download it within 2 minutes once you complete the payment.
- Your payment is secure and delivery of the manual is INSTANT – You will be redirected to the DOWNLOAD PAGE.
- So do not hesitate and write to us for any questions you may have: heydownloadss @gmail.com
S.M